DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual

Figure 3 - 75 LLDP Local Port Information (Show Detail) window

To return to the LLDP Local Port Information window click the <<Back button.

LLDP Remote Port Information

This window displays port information learned from the neighbor. The switch receives packets from a remote station but is able to store the information as local.

To view this window, click L2 Features > LLDP > LLDP Remote Port Information as shown below:

Figure 3 - 76 LLDP Remote Port Information window

Select the port you wish to view by using the drop-down menu and click Find the information will be displayed in the lower half of the table. To view the settings for an individual port select the port and click Show Normal which will display the following window.

Figure 3 - 77 LLDP Remote Port Information (Show Normal) window

CFM

Connectivity Fault Management (CFM) is defined by IEEE 802.1ag, which is a standard for detecting, isolating and reporting connectivity faults in a network. CFM is an end-to-end per-service-instance Ethernet layer operation, administration, and management (OAM) function. CFM functions include path discovery, fault detection and fault verification and isolation as defined by 802.1ag.

Ethernet CFM frames have a special Ether Type (0x8902). All CFM messages are confined to a maintenance domain per VLAN basis. There are different message types which are identified by unique Opcode of the CFM frame payload.

CFM message types that are supported include; Continuity Check Message (CCM), Loopback Message and Response (LBM, LBR) and Linktrace Message and Response (LTM and LTR).

CFM Port Settings

This table is used to enable or disable the connectivity fault management function on a per port basis. CFM is disabled on all ports by default.

To view this window, click L2 Features > CFM > CFM Port Settings as shown below:

123

Page 134
Image 134
D-Link DGS-3700 user manual Lldp Remote Port Information, CFM Port Settings