DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual

sFlow Counter Poller Settings

This window is used to create the sflow counter poller settings on the Switch. Within the sflow counter poller function, the port statistics counter information will be forwarded to the server at the configured interval. These counters are RFC 2233 counters.

To view this window, click Configuration > sFlow > sFlow Counter Poller Settings as shown below:

 

Figure 2 - 58 sFlow Counter Poller Settings window

The following parameters can be configured:

 

 

Parameter

Description

 

 

From Port / To Port

Specifies the port or list of ports to be configured.

 

 

Analyzer Server ID

The analyzer server id specifies the ID of a server analyzer where the packet will be

(1-4)

forwarded.

 

 

Interval (20-120)

Specifies the maximum number of seconds between successive statistic counter information.

 

To disable the interval check the Disabled box.

Click Apply to implement the changes made.

50

Page 61
Image 61
D-Link DGS-3700 user manual SFlow Counter Poller Settings, Following parameters can be configured