DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual

 

 

 

 

 

 

Leave All Time

The time in milliseconds that specifies the amount of time the Switch will take to Leave All

 

 

(100-100000)

groups. The default is 10000. The Leave All Time must be greater than the Leave Time.

 

 

NNI BPDU

This specifies the GVRP’s pdu MAC address of the NNI port.

 

 

Address

Dot1d – Specifies GVRP’s pdu MAC address of NNI port using 802.1d.

 

 

 

 

 

 

Dot1ad – Specifies GVRP’s pdu MAC address of NNI port using 802.1ad.

 

 

 

 

 

 

Click Apply to implement changes made.

 

MAC-based VLAN Settings

This table is used to create MAC-based VLAN entries on the switch. A MAC Address can be mapped to any existing static VLAN and multiple MAC addresses can be mapped to the same VLAN. When a static MAC-based VLAN entry is created for a user, the traffic from this user is able to be serviced under the specified VLAN regardless of the authentiucation function operated on the port. Therefore each entry specifies a relationship of a source MAC address with a VLAN.

To view this window, click L2 Features > MAC-based VLAN Settings as shown below:

Figure 3 - 21 MAC-based VLAN Settings window

The following fields can be set

Parameter Description

MAC Address

Specify the MAC address to be reauthenticated by entering it into the MAC Address field.

 

 

VLAN Name

Enter the VLAN name of a previously configured VLAN.

 

 

Click Find, Add or Delete All for changes to take affect.

PVID Auto Assign Settings

This commands Enables or Disables PVID Auto Assign on the Switch. PVID is the VLAN that the switch will use for forwarding and filtering purposes. If PVID Auto-Assign is Enabled, PVID will be possibly changed by previously set PVID or VLAN configurations. When a user configures a port to VLAN X’s untagged membership, this port’s PVID will be updated with VLAN X. In the form of a VLAN list command, PVID is updated with the last item on the VLAN list. When a user removes a port from the untagged membership of the PVID’s VLAN, the port’s PVID will be assigned to a default VLAN. When PVID Auto Assign is Disabled, PVID can only be changed by PVID configuration (user changes explicitly). The VLAN configuration will not automatically change the PVID. The default setting is Enabled.

To view this window, click L2 Features > PVID Auto Assign Settings as shown below:

Figure 3 - 22 PVID Auto Assign Settings window

86

Page 97
Image 97
D-Link DGS-3700 user manual MAC-based Vlan Settings, Pvid Auto Assign Settings, Leave All Time, NNI Bpdu