DGS-3700-12/DGS-3700-12G Series Layer 2 Gigabit Ethernet Switch User Manual
215
Figure 6 - 42 CPU Access Rule Detail Information window for IP
To establish the rule for a previously created CPU Access Profile:
To configure the Access Rules for IP, open the CPU Access Profile List window and c lick Add/View Rules for an
IPv6 entry. This will open the following window.
Figure 6 - 43 CPU Access Rule List window for IPv6
To remove a previously created rule, click the corresponding Delete Rul es button. To add a new Access Rule, click
the Add Rule button:
Figure 6 - 44 Add Access Rule window for IPv6
To set the Access Rule for IPv6, adjust the following parameters and click Apply.
Parameter Description
Access ID (1-100) Enter a unique identifier number for this access. This value can be set from 1 to 100.
Action Select Permit to specify that the p ackets that match the access profile are f orwarded by the
Switch, according to any additional rule added (see below).
Select Deny to specify the packets that match the access profile to be fi ltered.
Class Enter an IPv6 Class. The class can be between 0255.
Flow Label Configuring this field, in hex form, will instruct the Switch to examine the flow label field of the
IPv6 header. This flow label field is used by a source to labe l se que nc es of pac k et s s uc h as n on-