NEC NEAX 2000 specifications Do Not Disturb System

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 182
Image 182

DO NOT DISTURB

Do Not Disturb - System

9.Call Back cannot be set to stations in DND.

10.Recalls will override the DND setting, and ring back to a station in DND.

Do Not Disturb - System

General Description

This feature simultaneously restricts incoming calls to a preassigned group of stations by operation from the Ho- tel/Motel Front Desk Instrument(s). Attendant Console(s) and Hotel/Motel Front Desk Instruments can use the DND OVR key to override this Do Not Disturb setting.

Station Application

All stations.

Operating Procedure

To set Do Not Disturb - System from the Hotel/Motel Front Desk Instrument

1.Press the DD key.

2.Press the GROUP key.

3.Press the SET key.

4.Press the RLS key.

To cancel Do Not Disturb - System from the Hotel/Motel Front Desk Instrument

1.Press the DD key.

2.Press the GROUP key.

3.Press the RESET key.

4.Press the RLS key.

Service Conditions

1.Stations are assigned to the Do Not Disturb (DND) Group in Class of Service.

2.Calls to extensions whose stations are in Do Not Disturb will receive reorder tone.

3.The station in Do Not Disturb can originate calls in the normal manner.

4.Verification of stations in Do Not Disturb is possible from the Hotel/Motel Front Desk Instrument and At- tendant Consoles.

5.The ability to set DND is both on a per-station basis, and a per-system (for DND group) basis.

6.Only Hotel/Motel Front Desk Instruments and Attendant Consoles have the ability to place a group of sta- tions in Do Not Disturb. There is only one group available, and the stations within the group are pro- grammed in system data. There is no limitation on the number of stations in the group.

7.A station included in a DND group retains the ability to place that particular station in DND.

8.When the Hotel/Motel Front Desk Instrument places a group in DND, an individual station within the group can cancel the DND setting to that station.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 159

NDA-24271, Issue 1.0

Page 182
Image 182