OFF-PREMISES EXTENSIONS

OFF-PREMISES EXTENSIONS

General Description

This feature allows the connection of a single line telephone in an off-premises location. The connection to the Off-Premises Extension can be through direct copper or through the local telephone company.

Station Application

Single Line Stations.

Operating Procedure

Normal operating procedures apply.

Service Conditions

1.A PN-AUCA is required for connection of Off-Premises Extensions. The PN-AUCA is a 2-circuit card.

2.The maximum loop resistance for an Off-Premises Extension is 2500 ohms, inclusive of the resistance of the telephone.

3.Message Waiting is not available for Off-Premises Extensions.

4.Disconnect supervision is not available on Off-Premises Extensions.