NEC NEAX 2000 specifications Station Set Call Forwarding Billing Object

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 99
Image 99

CALL FORWARDING

Call Forwarding – All Calls

6.A maximum of 26 digits (without access code) can be stored for Call Forwarding – All Calls to an outside number.

7.Call Forwarding – All Calls to an outside number can be routed by the Least Cost Routing feature and re- stricted by the Code Restriction feature.

8.More than one Call Forward can occur in the progress of a call. See Multiple Call Forwarding – All Calls, Multiple Call Forwarding – Busy Line, and Multiple Call Forwarding – No Answer.

9.Direct Inward Dial (DID) lines, DIT calls, Tie lines, ring transfer and internal incoming calls will follow the Call Forward setting.

10.Only the destination station can call the station that is Call Forwarded.

11.If the Call Forward is rerouted to a hunt group and all members of the hunt group are busy, the forwarded caller will receive busy tone.

12.If the Call Forward is rerouted to the pilot number of an Automatic/Uniform Call Distribution (UCD) group and that pilot station has set Call Forward, the call will be forwarded.

13.When Call Forwarding – All Calls – Outside is set, the system can be programmed to allow or deny the set- ting of the Call Forward with only a trunk access code. This can be set on a system-wide basis.

14.In the SMDR call record, the station that set Call Forwarding – All Calls – Outside will appear as the orig- inator of the call.

15.SMDR only records if the Tandem Connection receives answer supervision.

16.The setting station's trunk restriction class is used to allow or deny the tandem connection on a Call For- warding – All Calls – Outside.

17.Checking of the setting station's trunk restriction class can be allowed or denied on a system-wide basis.

18.A Direct Inward System Access (DISA) call to a station set for Call Forwarding – All Calls Outside will be allowed or denied based on the forwarded station's trunk restriction class.

19.An internal station call to a station set for Call Forwarding – All Calls Outside will follow the restriction class of the station set Call Forwarding.

When Call Forwarding to outside is executed, an object of the billing is as follows.

Station Set Call Forwarding

Billing Object

 

 

Single Line Telephone,

Station set Call Forwarding

Multiline Terminal

 

 

 

Virtual station

Originating station/trunk

 

 

20.When the station user that has set Call Forwarding lifts the handset, the station can receive special dial tone by system programming.

21.A maximum of 496 Call Forwarding setting to outside number is allowed per system, including Call For- warding – All Calls, Busy Line, No Answer.

• MP without expansion memory (standard) : up to 240 setting

• MP with expansion memory (optional)