NEC NEAX 2000 specifications Attendant Called/Calling Name Display

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 44
Image 44

ATTENDANT CONSOLE

Attendant Called/Calling Name Display

Service Conditions

1.Each Firmware Processor (FP) can support up to 8 Attendant Consoles (SN610 ATTCON/SN716 DESKCON). A maximum of 8 Attendant Consoles (SN610 ATTCON/SN716 DESKCON) can be support- ed per system.

2.Each SN716 DESKCON uses a 3-pair cable. This cable cannot be longer than 4000 feet (1200 meters).

3.The SN716 DESKCON is equipped with an Alarm LED. This LED will flash for Minor Alarms and light steadily for Major Alarms. Refer to Maintenance Administration Terminal, Fault Messages for more infor- mation. Refer to the following chart for cable distances.

4.Refer to the following chart for cable distances:

 

With PW00

With AC/DC Adapter

 

 

 

4 port DLC and 2 DLCC

1000 feet (304 meters)

4000 feet (1219 meters)

 

 

 

8 port DLC

1000 feet (304 meters)

1000 feet (304 meters)

 

 

 

Note: The SN716 DESKCON uses the PW00 card mounted in the PBX, or the Dterm Series E AC/DC Adapter, not both.

5.The SN716 DESKCON does not support the Lockout feature. Position Busy replaces the Lockout feature.

6.The system does not support Busy Lamp Field on the keypad.

7.The system does not support REC, EMG, TKSL, SVC, MODE key on the console.

8.The following key assignments are fixed and cannot be changed by system programming:

PAGE, BV, CALL PARK, SC, START, MUTE.

Attendant Called/Calling Name Display

General Description

This feature provides a display of the calling/called party's name on the Attendant Console LCD for Attendant Called/Calling Name Display. On attendant-to-station calls, the LCD display the name assigned to the primary extension of the station. On attendant-to-trunk calls, the LCD displays the name assigned to the trunk route of the trunk.

Station Application

Attendant Console.

Operating Procedure

Displays are automatically provided by the system, once programmed.

Service Conditions

1.A maximum of 512 stations can be provided with a user's name display. The maximum number of characters per name is 16 (including spaces). The Maintenance Administration Terminal (MAT) or Customer Admin- istration Terminal (CAT) can be used to register or change a name. Multiline Terminal users can record or change the name assignment for their own individual Multiline Terminal.

2.User names can be assigned to stations that do not have an LCD display (including Single Line Stations).

NEAX2000 IVS2

 