NEC NEAX 2000 specifications Pushbutton Calling Attendant Only, Serial Call

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 62
Image 62

ATTENDANT CONSOLE

Pushbutton Calling – Attendant Only

6.The system operates only on a switched-loop basis. Fixed-loop operation is not available.

7.To place a multiple console system (or a multiple console tenant group) into Night Service, a prepro- grammed master console must press the MODE, NITE and Answer key (press Night key for SN716 DESKCON). If one of the other consoles enters Night Service, all calls addressed to that console will be directed to the other console(s).

8.When a console has entered Night Service, all calls already connected to its loop must be processed from that console. Recalls and serial recalls are routed to the night transfer station, if assigned.

Pushbutton Calling – Attendant Only

General Description

This feature permits an operator to place all calls over Dual-Tone, Multi-Frequency (DTMF) lines from the push-button keypad on the Attendant Console.

Operating Procedure

The operator presses the push-button keypad to dial.

Service Conditions

1.This feature requires that all Central Office trunks or tie trunks accept push-button signaling (DTMF).

2.Push-button Calling- Attendant Only may be added to the system without providing push-button calling ca- pability to other stations.

Serial Call

General Description

This feature is activated by the Attendant when an incoming calling party wishes to speak with more than one internal party. When the internal station subsequently disconnects from the C.O. line call, the C.O. party auto- matically rings back to the same Attendant.

Operating Procedure

1.The Attendant answers an incoming C.O. call.

2.The Attendant extends the call to the desired station.

3.The Attendant presses the SERIAL CALL SET (SC) key.

4.The called station and incoming caller are connected.

5.The called station hangs up. The Serial Call Termination (SRL) LED on the Attendant Console flashes at 60 IPM. If the Attendant is available, an audible indication is provided.

6.The Attendant presses the Answer or SRL key to return to the original incoming calling party.

Service Conditions

1.Serial Calling is not provided for Station-to-Station calling.

2.Serial Calling can be enabled or disabled on a per-console basis.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 39

NDA-24271, Issue 1.0

Page 62
Image 62
NEC NEAX 2000 specifications Pushbutton Calling Attendant Only, Serial Call