FLEXIBLE NUMBERING PLAN
FLEXIBLE NUMBERING PLAN
General Description
The system has a Flexible Numbering Plan. All access codes and station numbers and can be assigned in system programming. Refer also to the Single Digit Dialing Features and Specifications which further increases the flexibility of the system.
Station Application
All stations.
Operating Procedure
Normal call handling procedures apply.
Service Conditions
1.The system is provided with a Resident System Program; however, the flexibility of the system allows all access codes and station numbers to be changed to any desired number (from one to three digits for access codes, and one to 8 digits for station numbers), provided access codes and station numbers do not conflict with each other.
2.Up to four different numbering plans may be assigned in the same system. When there are multiple tenants, any one of the four numbering plans can be assigned to each tenant.
3.Any combination of 1 to 8 digits can be assigned as station numbers within the same numbering plan. When assigning different amounts of digits to stations the leading digits of the shorter extension numbers cannot be the same as the leading digits of the longer extension numbers. For example: extensions 60 and 607 can- not be assigned in the same numbering plan.
4.The system can also be programmed to provide a group of fixed
Access Code | Feature |
2Call Back, Trunk Queuing Outgoing
3Executive Override
4
5
6Message Reminder
*Step Call
The following feature access codes can be dialed while receiving ringback tone:
Access Code | Feature |
1Internal Voice/Tone Signaling
2Call Back
6Message Reminder
5.The
NEAX2000 IVS2 |
|
Business/Hotel/Data Features and Specifications | Page 171 |