DISTINCTIVE RINGING

DISTINCTIVE RINGING

General Description

This feature provides Distinctive Ringing patterns to the station so that the station user can distinguish between internal and external incoming calls. This feature also enables the LED associated with the line key of the Mul- tiline Terminal to flash in two colors according to the kind of incoming call.

Station Application

All stations.

Operating Procedure

No manual operation is required.

Service Conditions

1. Ringing pattern for incoming internal calls:

1 second on, 2 seconds off

OR

2 seconds on, 4 seconds off

2.Ringing pattern for incoming external calls: 1 second on, 2 seconds off

OR

2 seconds on, 4 seconds off

OR

0.4seconds on, 0.2 seconds off

0.4seconds on, 2.0 seconds off

3.Ringing pattern for Call Back, Trunk Queuing - Outgoing and Executive Calling:

0.5seconds on, 0.5 seconds off

0.5seconds on, 1.5 seconds off

4.All recalls (to Multiline Terminals):

0.5seconds on, 0.5 seconds off

0.5 seconds on, 0.5 seconds off

5.When calling a third station (three-party Conference, Consultation Hold, etc.), the ringing signal sent to the called station is dependent upon the type of call placed on Hold. If the call is a trunk call, external ringing is provided; if the call is an extension call, internal ringing is provided.

6.Ring frequencies of Multiline Terminals can be assigned in programming through station Class of Service. Refer to the Ring Frequency Control Features and Specifications.

7.The ringing pattern for incoming internal calls is programmable on a system basis.

8.The ringing pattern for incoming external calls is programmable on per trunk route basis.

9.The ringing pattern of recalls to Single Line Telephones is the same pattern as that of the original call.

10.The distinctive lamp indication is applicable only for Multiline Terminals during call termination (including a recall).

NEAX2000 IVS2

 