NEC NEAX 2000 specifications Direct Digital Interface

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 162
Image 162

DIRECT DIGITAL INTERFACE

DIRECT DIGITAL INTERFACE

General Description

This service feature provides the capability to connect trunks from the NEAX2000 IVS2 directly to T1 carrier links using either a private or public network.

 

 

DS-1 signal level

 

 

 

PCM transmission line

 

 

 

(24 channel)

 

NEAX2000 IVS2

 

 

 

 

 

 

Digital

 

 

 

PABX

OFFICE

LINE

LINE

OFFICE

REP

REP

REP

REP

Operating Procedure

No manual operation is required.

Service Conditions

1.Each Office Hierarchy is defined as follows:

a.Source office

One center will operate as the Source Office. This location has two highly stabilized source oscillators, and distributes the Source Clock to all the systems through the Digital Interface lines.

b.Sub-Source office

This office operates using a Phase Lock Oscillator (PLO) to synchronize with the clock at the Source Office. If the Source Clock fails, the Sub-Source office can operate using its own backup oscillator.

c.Receiver office

This office is arranged so it will have at least two clock routes, one for Source and the other for standby. Synchronization Clock is derived from incoming PCM bit stream from higher hierarchy offices.

d.Local Receiver office

This is the end office in a digital network arrangement. This office will not be provided with a backup route for the PLO because this office is the only one influenced in the event of trouble occurrence.

2.When a digital network is implemented using the NEAX2000 IVS2, the NEAX2400 IMX can function as a Source office or Sub-Source office while the NEAX2000 IVS2 functions as a Receiver and/or Local Receiv- er office.

3.Each digital office is equipped with a PLO used for network synchronization. Clocks from the Source Os- cillator or Digital Interface Package should be connected to inputs on each PLO.

4.D3 Channel Banks are not required since the switch can be equipped with a Digital Trunk Interface (DTI) compatible with DS-1 signal level.

5.The DTI provides signalling interface, bipolar/unipolar conversion, frame synchronization, insertion/ex- traction and alarm detection.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 139

NDA-24271, Issue 1.0

Page 162
Image 162
NEC NEAX 2000 specifications Direct Digital Interface