VARIABLE TIMING PARAMETERS

VARIABLE TIMING PARAMETERS

General Description

This feature gives the system the versatility to change timing duration using the Maintenance Administration Terminal (MAT) or the Customer Administration Terminal (CAT). All timing parameters are set initially in the Resident System Program. These timing parameters can be changed according to the customer's requirements.

Station Application

Not applicable.

Operating Procedure

Refer to the Feature Programming Manual for programming instructions.

Service Conditions

The Feature Programming Manual contains instructions on how to change the following timing durations:

 

 

 

Duration (in sec. unless otherwise marked)

 

 

 

 

 

 

 

 

Standard

 

 

 

 

 

Parameter

Timing

 

 

 

 

Variable Timing

 

 

 

 

 

 

Automatic Recall of Attendant transferred Camp-On

31.2

- 33.6

 

0.0 - 124.8

(2.4-sec. increments in 2.4 - 33.6 sec.

and unanswered calls

 

 

 

 

9.6-sec. increments in 28.8 - 124.8 sec.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elapsed time before Call Forwarding - No Answer

 

 

 

 

 

 

 

for incoming trunk calls or Attendant Overflow acti-

32

- 36

 

0

- 120 (4-sec. increments)

vation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Station Message Detail Recording (SMDR) valid

20

- 24

 

8

- 40

 

 

call timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect recognition time for trunks

0.96

- 1.44

 

0

- 6.72

(0.48-sec. increments)

 

 

 

 

 

 

Recall timing for Exclusive Hold

236

- 240

 

0 - 396

(4-sec. increments)

 

 

 

 

 

 

Recall timing for Nonexclusive Hold and Call Park

60

- 64

 

0 - 396

(4-sec. increments)

 

 

 

 

 

 

 

Recall timing after station release for Call Transfer

24

- 28

 

0

- 120

(4-sec. increments)

 

 

 

 

 

Periodic Time Indication Tone interval

180

- 184

 

32 - 724 (60-sec. increments)

 

 

 

 

 

 

 

 

Automatic cancel time for unanswered external pag-

300

 

60 - 900 (60-sec. increments)

ing calls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reorder tone timeout to enter Line Lockout state and

28

- 32

 

4

- 32 (4-sec. increments)

Off-Hook Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ringing duration of Automatic Wake Up call (Timed

28

- 32

 

0

- 32 (4-sec. increments)

Reminder)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single digit dialing timer (Timing Start)

4

- 5

 

2

- 8 (1-sec. increments)

 

 

 

 

 

 

 

 

Maximum Automatic/Uniform Call Distribution

 

 

 

 

 

 

 

(ACD/UCD) call waiting time before answer or

44

- 52

 

12 - 136 (4-sec. increments)

abandonment for Peg Count

 

 

 

 

 

 

 

 

 

 

 

 

 

Automatic recall of Camp-On

24

- 32

 

8 - 128

(8-sec. increments)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 