MESSAGE WAITING
8.When the user of a station that has a Message Waiting indication lifts the handset, the station can receive special dial tone by system programming. It reminds the station user that a message is waiting.
Voice Message Waiting - System/Individual
1.A maximum of 10 messages can be recorded for Voice Message Waiting - System. A maximum of 128 messages can be set simultaneously for Voice Message Waiting - Individual. One Voice Recording Mem- ory port per message is required.
2.The duration of an announcement is limited to 60 seconds in Voice Message Waiting - System/Individual.
3.Voice Message Waiting - System/Individual can be automatically cleared by retrieving a message from a set station.
4.For the Voice Message Waiting - System, more than one connection can be made to a Digital Announce- ment Trunk. Secondary connections can be made in the middle of a message. For the Voice Message Wait- ing - Individual, only one station can be connected to each Digital Announcement Trunk Card at a time.
5.Any operations for Voice Message Waiting - System/Individual are not available from a station with a call in Consultation Hold.
6.The message is repeated until the station goes on hook.
7.Voice Message Waiting - System/Individual can be provided on a system basis.
NEAX2000 IVS2 |
|
Business/Hotel/Data Features and Specifications | Page 223 |