VARIABLE TIMING PARAMETERS

 

 

 

Duration (in sec. unless otherwise marked)

 

 

 

 

 

 

Standard

 

 

 

Parameter

Timing

 

 

Variable Timing

 

 

 

 

 

 

Timing before unanswered Automated Attendant

32

- 36

 

0 - 120 (4-sec. increments)

call forwards

 

 

 

 

 

 

 

 

 

 

 

Interval time between attempts for Timed Queue

120

- 124

 

44 - 124 (4-sec. increments)

 

 

 

 

 

Duration of call by Timed Queue

28

- 32

 

16 - 124 (4-sec. increments)

 

 

 

 

 

 

Programmable pause for System and Station Speed

1.5

 

1.5, 3, 4.5, 6, 8, 10, or 12

Dialing

 

 

 

 

 

 

 

 

 

 

 

Night Service announcement timer

60

- 64

 

0 - 120 (4-sec. increments)

 

 

 

 

 

 

Timing of Multiple Call Forwarding - No Answer

32

- 36

 

0 - 120 (4-sec. increments)

(after second forwarding)

 

 

 

 

 

 

 

 

 

 

 

Interval time of UCD delay announcement

32

- 36

 

0 - 120 (4-sec. increments)

 

 

 

 

 

 

Automatic Recall of Attendant-held calls

31.2

- 33.6

 

0.0 - 124.8

(2.4-sec. increments in 2.4 - 33.6 sec.

 

 

9.6-sec. increments in 38.4 - 124.8 sec.)

 

 

 

 

 

 

 

 

 

 

 

Elapsed Time before Call Forward-No Answer for

32

- 36

 

0 - 120 (4-sec. increments)

internal and assisted calls

 

 

 

 

 

 

 

 

 

 

 

 

Message Replay Timer for Automatic Wake-Up/

60

- 64

 

0 - 396 (4-sec. increments)

Timed Reminder

 

 

 

 

 

 

 

 

 

 

 

 

Message Relay Timer for Announcement Service

60

- 64

 

0 - 396

 

 

 

 

 

 

 

Forced Disconnection Timer on Tandem Connection

204

- 238

 

136 - 544 minutes (34-minute increments)

minutes

 

 

 

 

 

 

 

 

 

 

 

 

NEAX2000 IVS2

Page 328

Business/Hotel/Data Features and Specifications

NDA-24271, Issue 1.0

Page 351
Image 351