NIGHT SERVICE

Night Connection - Flexible

3.The night station goes off-hook and answers the call. If necessary, the answered call can be transferred to another station or outside party.

Service Conditions

1.Night Connection station can be assigned the following types of trunks:

Direct Distance Dialing (DDD)

Foreign Exchange (FX)

Wide Area Telephone Service (WATS)

Common Control Switching Arrangement (CCSA)

Direct Inward Dialing (DID) (available only for LDN calls)

TIE (available only for operator calls)

2.Each night station can be assigned multiple trunks.

3.A fully restricted station cannot be assigned as a night station.

4.If the night station to which an incoming call has been terminated is busy, the system can be programmed to provide one of the following choices on a per-trunk basis:

Automatic Camp-On

Trunk Answer Any Station

Ringback tone.

5.If the night station does not answer after a predetermined time, the system can provide one of the following options on a per-trunk basis:

Trunk Answer Any Station

Ringback tone.

6.The night station can be assigned to a Station Hunting Group.

7.The night station can be assigned to an Automatic/Uniform Call Distribution (UCD) group.

8.If the night station has set Call Forwarding, incoming calls terminated to that station will be forwarded to the destination station.

9.If the night station has set Call Forwarding to the Attendant, this setting will be ignored and incoming calls will terminate to the night station.

10.Night stations can access Call Hold, Call Transfer, and Conference provided these features are programmed into its Class of Service.

Night Connection - Flexible

General Description

This feature provides incoming calls normally terminated to the fixed night station to be Call Forwarded to an- other station.