NEC NEAX 2000 specifications Press the WK UP key Press the Reset key Press the RLS key

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 86
Image 86

AUTOMATIC WAKE-UP

To set Automatic Wake-Up from the Hotel/Motel Front Desk Instrument while engaged in conversation with the station

1.Press the WK UP key.

2.Dial the wake-up time in military format (in one minute increments).

3.Press the SET key.

4.Press the RLS key.

To cancel Automatic Wake-Up from the Hotel/ Motel Front Desk Instrument wile engaged in conversation with station

1.Press the WK UP key.

2.Press the RESET key.

3.Press the RLS key.

To set Automatic Wake-Up from a guest room station or administrative station

1.Go off-hook and receive dial tone.

2.Dial the Wake-Up access code and receive feature dial tone.

3.Dial the desired Wake-Up time in military format (in one minute increments).

4.Receive service set tone.

5.Restore the handset.

To cancel Automatic Wake-Up from a guest room station or station or administrative station

1.Go off-hook and receive dial tone.

2.Dial the Automatic Wake-Up cancellation code.

3.Receive service set tone.

4.Restore the handset.

Service Conditions

1.Setting and canceling can be initiated from the following:

Attendant Console

Hotel/Motel Front Desk Instrument

Guest Station

Administrative Station

Property Management System (PMS) terminal

2.A maximum of 32 stations can be set for the same Automatic Wake-Up time. When the setting exceeds 32, the excess stations will be set to an earlier time in 5 minute intervals.

3.Wake-Up attempts, whether successful or not, can be printed out at a locally provided printer. The results of execution of Automatic Wake-Up set and cancel are also printed.

4.The ringing signal is the same as station-to-station calls, and its time can be assigned from 4 sec. to 32 sec. (programmable on a system basis).

5.The Automatic Wake-Up call will ring a station in Do Not Disturb.

6.When setting or canceling has been completed, service set tone is heard as confirmation.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 63

NDA-24271, Issue 1.0

Page 86
Image 86
NEC NEAX 2000 specifications Press the WK UP key Press the Reset key Press the RLS key