SECURITY ALARM

SECURITY ALARM

General Description

This feature provides an indication on the Attendant Console when a contact closure occurs.

Station Application

Not applicable.

Operating Procedure

No manual operation is required.

Service Conditions

1.The contact to be monitored is connected across Tip (T) and Ring (R) of one circuit on a 4LC/8LC card.

2.The contact installed must be a normally open contact.

3.The contact generated signal is non-latching; therefore, if the contact opens again, the signal to the Atten- dant Console stops.

4.The station number assigned to the single line circuit associated with the contact closure is displayed when the Attendant presses the ATND key or Answer key.

5.Assignment of this feature is accomplished using Hotline assignment of a single line extension to the At- tendant Console. Refer to the Hotline - Inside/Outside Features and Specifications for more information.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 283

NDA-24271, Issue 1.0