DIRECT STATION SELECTION/BUSY LAMP FIELD (DSS/BLF) CONSOLE
Room Cutoff Console
Station Application
All stations with a DSS/BLF Console.
Operating Procedure
To set and cancel Message Waiting
1.Press the MW key. When stations are currently in MW their associated LED will light green.
2.Press the Function Mode key: an LED associated with the Function Mode key will light red.
3.Press the desired DSS key(s) to set or cancel. A lit LED indicates MW has been set.
4.Press the MW key again to return to DSS/BLF mode, if desired.
Service Conditions
1.The MW Console only displays/cancels the set status for those stations to whom Message Wait was set, by the station user of the MW Console.
2.If the system is initialized (reset), the Console function mode will return to DSS/BLF.
3.Refer to the DSS/BLF Console and the Message Waiting Features and Specifications for more details.
Room Cutoff Console
General Description
This feature allows a DSS/BLF Console associated with a Multiline Terminal to be used as a Room Cutoff Con- sole. This feature is activated by the use of a Function Mode key on a DSS/BLF Console. The Room Cutoff status for each station is indicated by a green LED associated with each button. In addition, the Multiline Ter- minal user can set/cancel Room Cutoff to another station using the Room Cutoff Console.
Station Application
All Multiline Terminals with a DSS/BLF Console.
Operating Procedure
To set and cancel Room Cutoff
1.Press the RC key. When stations are currently in RC their associated LED will light green.
2.Press the Function Mode key: an LED associated with the Function Mode key will light red.
3.Press the desired DSS key(s) to set or cancel. A lit LED indicates RC has been set.
4.Press the RC key again to return to the DSS/BLF mode, if desired.
Service Conditions
1.The Room Cutoff Console only displays/cancels the set status for those stations which were set into room cutoff by the station user of the Room Cutoff Console. Indication is not provided when another Room Cut- off console, the Attendant Console, a Hotel/Motel Front Desk Instrument, or a PMS changes the RC status of a station.
2.If the system is initialized (reset), the Console function mode returns to DSS/BLF.
3.Refer to the DSS/BLF Console and the Room Cutoff Features and Specifications for more details.
NEAX2000 IVS2 |
|
Business/Hotel/Data Features and Specifications | Page 151 |