RESIDENT SYSTEM PROGRAM

RESIDENT SYSTEM PROGRAM

General Description

This feature provides the installers a simple procedure to have the system generate system data according to the system hardware configuration, thereby providing immediate operation and shorter programming time. When activated, the system scans hardware configuration (such as line/trunk card slot location) and assigns system data (such as extension numbers, trunk numbers, etc.) according to a predetermined generic program assignment.

Station Application

Not applicable.

Operating Procedure

Refer to the Command Manual for activation procedures.

Service Conditions

1.This feature is only applicable for equipment installed in Port Interface Module (PIM) 0 to 3.

2.System data is not assigned to any vacant slot.

3.Virtual extensions are not assigned.

4.The Resident System Program scans the hardware configuration.

5.Details of Resident System Program:

a.Extension Numbers:

Extension Numbers 200 through 455 are assigned according to sequential slot location number of the associated circuit boards.

b.SN610 ATTCON Numbers:

Attendant Console Numbers E004 through E007 are assigned according to sequential slot location numbers of the associated circuit card.

c.Trunk Numbers:

Trunk Numbers 000 through 255 are assigned according to sequential slot location number of the associated circuit boards.

d.Multifrequency Receivers (8RSTA)/External Equipment and Key Interface (DK00)/Extension Memory for AP00/Digital Announcement Trunk (2DAT):

Consecutive circuit numbers beginning at 00 are assigned according to sequential slot location number of the associated circuit boards.

e.Extension data:

Following data is assigned on a per extension basis.

Type of dial signal: Dual-Tone, Multi-Frequency (DTMF) for Single Line Telephones

f.Trunk data:

Following data is assigned on a per-trunk basis.

Trunk Route Numbers:

00 for C.O. Lines

01 for 2 Wire E&M Tie Lines

NEAX2000 IVS2

 