NEC NEAX 2000 specifications ADD-ON Module

Models: NEAX 2000

1 367
Download 367 pages 36.36 Kb
Page 26
Image 26

ADD-ON MODULE

ADD-ON MODULE

General Description

This feature allows the Add-On Module to be combined with a Multiline Terminal when there are insufficient line or trunk keys provided at the Multiline Terminal.

When the Add-On Module unit keys are programmed as line/trunk keys, the additional 25 lines/trunks and the existing lines/trunks set for the Multiline Terminal can be accessed directly (maximum of 49 lines/ trunks).

The station speed dialing function can be assigned for all keys on the Add-On Module unit. Also, one of the last 3 keys can be used as a Day/ Night change key.

Station Application

All Multiline Terminals (Dterm Series III/Series E).

Operating Procedure

The operating procedure as an Add-On Module is the same as that of the Multiline Terminal.

If any key on the Add-On Module unit is used for station speed dialing, the operating procedure is the same as station speed dialing.

Service Conditions

1.The maximum number of Add-On Module units, per Firmware Processor (FP) is 32. The maximum number per system is 32.

2.Only one Add-On Module can be connected to a Multiline Terminal providing a maximum of up to 41 line/ trunk keys (16 line/trunk keys on Dterm Series III/Series E and 25 line/trunk keys on Add-On Module).

3.A Multiline Terminal and an associated Add-On Module unit must be contained in the same PIM.

4.The total of Multiline Terminals and Add-On Module units used as Add-On Modules:

• MP without expansion memory (standard) : 256 per system

• MP with expansion memory (optional)

: 512 per system

5.Trunks and lines (Prime Lines of other Multiline Terminals, virtual lines, and single lines) can be assigned to the Add-On Module unit lines and keys.

6.The following can also be set for line/trunk keys other than those mentioned in 5 above: house phones, Hot- lines, Manual Intercoms, Automatic Intercoms, and Dial Intercoms.

7.Lamp indication on the Add-On Module unit is the same as that of Multiline Terminals.

8.Boss/Secretary Transfer and override functions are available for line keys on the Add-On Module.

9.If a line/trunk on the Add-On Module unit is called, the ringer of the connected Multiline Terminal rings. The Multiline Terminal volume is used to control the ringer volume.

10.Data lines cannot be set to any line/trunk keys on the Add-On Module.

11.If the resident system program is used to set system data, the Add-On Module unit will be assigned as 16 lines on the Multiline Terminal.

12.For details on any keys usable for the station speed dialing function, refer to the Station Speed Dialing fea- ture. One of the last 3 keys can be used as Day/Night key.

NEAX2000 IVS2

 

Business/Hotel/Data Features and Specifications

Page 3

NDA-24271, Issue 1.0

Page 26