REMOTE PIM
REMOTE PIM
General Description
When the system has two or more PIMs, the PIMs can be installed separately by T1 digital interface. A maxi- mum of 3 PIMs can be installed apart at the remote site.
Station Application
All stations.
Operating Procedure
The same operating procedure as the regular NEAX2000 IVS2 apply for each service feature.
Service Conditions
1.The Main Site must be the NEAX2000 IVS2. The Small Platform System cannot be the Main Site.
2.Only one PIM is available at each Remote Site.
3.The Remote PIM can be installed at a maximum of 1312 ft. distance from the Main Site. The distance can be extended by using line extension equipment (repeater, MUX, etc.).
4.A maximum of 23 lines/trunks can be accommodated in one Remote PIM. Application processor cards can not be accommodated in Remote PIM.
5.When the link between the Main Site and the Remote Site has been lost for a certain duration, the system activates the PFT (Power Failure Transfer) automatically on the Remote Site, if it is provided.
6.The PIM for Remote Site requires the DAIB card.
7.The Wireless System is not available at the Remote Site according to the UTAM regulation.
8.Battery Backup Time: Using the internal battery kit, the Remote PIM, equipped with 23 ports, can operate up to 100 minutes (1 hour, 40 minutes) when AC power is lost.
9.The resident system programming cannot be set to the Remote Site while the Main Site is set.
NEAX2000 IVS2 |
|
Business/Hotel/Data Features and Specifications | Page 269 |