NAILED-DOWN CONNECTION - DATA

NAILED-DOWN CONNECTION - DATA

General Description

This feature provides Data Interface which can transmit the intra-office or inter-office digital data on fixed path connection.

The Data Interface equips the V.11 (X.21) interface.

A maximum data transmission speed of 64 Kbps is available.

Station Application

Not applicable.

Operating Procedure

No manual operation is required.

Service Conditions

1.This connection is assigned using the Maintenance Administration Terminal (MAT) or Customer Admin- istration Terminal (CAT) in the system data base.

2.The fixed connection is set automatically after initialization of the system.

3.If power failure occurs, the Nailed-Down Connection is lost until power is restored and the system has rein- itialized.

4.For this feature, it is necessary to install the Data Port Controller (DPC) card. And when providing the inter- office digital data transmission, it is necessary to install the Digital Trunk Interface (DTI) card in addition to the DPC card.

5.Refer to associated data features for more information on Data Communications.

 

NEAX2000 IVS2

Page 232

Business/Hotel/Data Features and Specifications

NDA-24271, Issue 1.0

Page 255
Image 255
NEC NEAX 2000 specifications NAILED-DOWN Connection Data