ALARM INDICATIONS
2.Normal operation of each Firmware Processor (FP) is indicated by a green flashing (120 int) “run” LED located on the FP.
3.Normal operation of the Main Processor (MP) is indicated by a green flashing (120 int) “run” LED located on the MP.
4.Normal operation of each AC/DC power supply is indicated by a steadily lit green LED located on the AC/ DC power supply.
5.In case that PBX is stopped at predetermined time, when PBX starts, fault message is stored and alarm is sent.
6.Alarm indication to Multiline Terminal lamp;
a.The maximum number of Multiline Terminals per system is two.
b.In case of MN alarm: Red flashing (60 int)
c.In case of MJ alarm: Red lighting (included MN + MJ)
d.When system/FP is reset after lighting alarm lamp, alarm indication will go off. (Fault information remains.)