RECYCLE mode. If the water/b rine temperatur e is high e nough, the s tart-up sequence
continues on to check the guide vane position. If the guide vanes are mor e t han 6% open, the
start-up waits un til the PIC close s the vanes. If th e vanes are clos ed, and the oil pu mp pressure
is less than 4 psid (28 kPad), th e oil pump rela y will then be e nergized. The PI C then waits unt il
the

OIL PRESS (Pressure) VERIFY TIME

(operator configured, default 15 seconds) for oil
pressure to reach 18 psid (124 kPad). After oil pressure is verified, the PIC waits 10 seconds,
and then the compressor start relay (1CR) is energized to start the compressor.
Failure to verify any of the requirements up t o this point will resu lt in the PIC aborti ng the start
and displaying the app lic a ble pre-start mode of failure on the LID defa ult screen. A pre-star t
failure does not advan c e th e starts in 12 hours count er. Any failure afte r the 1CR relay has
energized results in a safety shutdo wn, advances the sta rts in the 12 hours counter by one, and
displays the applicabl e shut-down status on t he LID display.
Click here f or Figure 25 — Control Sequence