Command Groups

max-association

This command configures the maximum number of clients that can be associated with the access point at the same time.

Syntax

max-association <count>

count is the maximum number of associated stations. Range: 0‐250

The maximum number of associations is 250 if you are NOT using encryption or authentication.

The maximum number of associations is 120 if you ARE using encryption or authentication.

Default Setting

100

Command Mode

Interface Configuration (Wireless)

Interface Configuration (Wireless): VAP

Command Usage

Use this command for the default interface or any of the seven VAPs configurable per radio interface.

Example

The following example shows setting the max‐association for the default interface and a VAP.

RoamAbout 3000#configure

Enter configuration commands, one per line. End with CTRL/Z

RoamAbout 3000(config)#interface wireless g

RoamAbout 3000(if-wireless g)#max-association 32

RoamAbout 3000(if-wireless g)#vap 1

RoamAbout 3000(if-wireless g: VAP[1])#max-association 10

RoamAbout 3000(if-wireless g: VAP[1])#end

RoamAbout 3000(if-wireless g)#