Enterasys Networks 9033900-04 manual Upgrading Firmware

Models: 9033900-04

1 316
Download 316 pages 29.09 Kb
Page 73
Image 73

Administration

Upgrading Firmware

You can upgrade the Access Point 3000 software from a local file on the management workstation, or from an FTP or TFTP server. New software may be provided periodically on the Wireless Web site (http://www.enterasys.com/products/wireless).

After upgrading new software, you must reboot the Access Point 3000 to implement the new code. Until a reboot occurs, the Access Point 3000 will continue to run the software it was using before the upgrade started.

Before upgrading new software, verify that the Access Point 3000 is connected to the network and has been configured with a compatible IP address and subnet mask.

Bulk upgrades can be done using Enterasys Networks NetSight Inventory Manager.

If you need to download from an FTP or TFTP server, perform the following additional tasks:

Obtain the IP address of the FTP or TFTP server where the access point software is stored.

Verify that the image is in the appropriate directory on the server.

If upgrading from an FTP server, be sure that you have an account configured on the server with a user name and password.

If VLANs are configured on the access point, determine the VLAN ID with which the FTP or TFTP server is associated, and then configure the management station, or the network port to which it is attached, with the same VLAN ID. If you are managing the access point from a wireless client, the VLAN ID for the wireless client must be configured on a RADIUS server.

RoamAbout Access Point 3000 Configuration Guide 4-39