Event Reporting and U-Abort Capabilities

Reconnected Event Report

This event report is generated under the following circumstances:

When an on-ECS station connects to a call that has been previously placed on hold. Reconnecting to a held call can be done either manually at the station (by reselecting the active call appearance or switch hook flash) or via a Third Party Reconnect capability.

NOTE:

An association requesting Third Party Reconnect capability (the association over which the capability was requested) receives an acknowledgement and does not receive a Reconnected Event Report. Event reports are sent over the other associations monitoring and/or controlling the call.

Reconnected Event Report Items

The following is a list of items provided with this report:

connected party number

The extension that has been reconnected to the call

call_id

This ECS-assigned call identifier is used to associate event reports to calls and identify a call the adjunct wants to control. The call identifier is unique within the ECS.

party_id

The ECS-assigned identifier that uniquely identifies a party on a call. The ECS provides the identifier and the adjunct should retain it for future operations. The party identifier is unique within the call_id.

3-50Issue 7 May 1998

Page 116
Image 116
Lucent Technologies 555-230-220 manual Reconnected Event Report Items