ASAI and Feature Interactions

receives the warning tone after the bridging is complete (provided the warning tone option is administered system-wide).

For a user-classified call, the observer is bridged on the connection when the destination answers. When the destination is a trunk with answer supervision (includes PRI), the observer is bridged on when actual far-end answer occurs. When the destination is a trunk without answer supervision, the observer is bridged on after trunk cut-through (timeout) event.

Applicable events are “connected” (when the observer is bridged on) with the observer’s extension, and “dropped” when the observer drops from the call. In addition, the observer may manipulate the call via Call Control requests to the same extent as via the station set.

Send DTMF cannot be used with Service Observing, if Service Observing is administered to receive warning tone. If a call is in service observing, a request to send DTMF digits is denied.

Single-Step Conference is allowed into a call that is being Service Observed without affecting the Service Observer.

Single-Digit Dialing and Mixed

Station Numbering

A call initiated using the Third Party Auto Dial capability is permitted to use single digit dialing.

Single-Step Conference

If multiple associations are involved with the resultant call after Single-Step Conference request, the other associations (those that did not request the feature) will each receive a Connected event report, if the request is successful. The association requesting a Single-Step Conference will only receive an acknowledgment.

A Single-Step Conference request will be denied if the call is in the process of being classified. A Single-Step Conference request is only accepted after the far end has answered and the call has been delivered to the ECS.

A station with manual origination Line Service will not be eligible for a Single-Step Conference. A station administered Without Hardware (AWOH) is eligible for Single-Step Conference.

Single-Step Conference does not change the conference controller, if one existed for the active call previously. If a conference controller did not exist prior to a Single-Step Conference, it will not exist after the Single-Step Conference either.

12-52Issue 7 May 1998