Event Reporting and U-Abort Capabilities

The call was redirected using the ASAI Redirect Call capability. However, if the Redirect Call request was sent over a domain control association, then that domain association receives an ACK, but does not receive the Call Redirected Event Report.

When the domain-controlled station is an analog phone and an alerting call is now alerting elsewhere (gone to coverage or redirected by ASAI Redirect Call), either:

The pick-up feature is used to answer a call alerting an analog principal’s station, or

An analog phone call is sent to coverage due to “no answer” (the analog set’s call is redirected).

This event report will not be sent if the Domain (Station) Control is never alerted or if it retains a simulated bridged appearance until the call is dropped/disconnected. Examples of situations when this event is not sent are:

Bridging

Call forwarding

Calls to a TEG (multifunction set with TEG button)

Cover-All

Coverage/Busy

Incoming PCOL calls (multifunction sets)

Pick-up for multifunction set principals

This event report never follows a Connected Event Report and is always preceded by an Alerting Event Report.

Call Redirected Report Items

The following is a list of the items provided with this report:

call_id

This ECS-assigned call identifier is used to associate event reports to calls and identify a call the adjunct wants to control. The call identifier is unique within ECS.

3-28Issue 7 May 1998