Event Reporting and U-Abort Capabilities

For G3V3 and later, the Multiple Monitors feature impacts transfer and conference situations as follows:

If the resultant call (after the conference or transfer) has ANY notification associations active, the ECS sends further Event Reports over the associations that were active for the resultant call. The ECS also sends the Call Ended Event Report over the notification associations for the other call.

Scenario 1: Call-1 has notification associations A1, A2. Call-2 has notification association A3. Call-2 is the resultant call.

After the merge (transfer, in this case) events are sent as follows:

A1: Call Ended

A2: Call Ended

A3: Call Transferred, further-events

If the resultant call (after the conference or transfer) has NO notification associations active, the ECS sends further Event Reports for the notification associations that were active for the other call. The Call Ended event is not sent over any notification associations.

Scenario 2: Call-1 has notification associations A1, A2. Call-2 has NO notification associations. Call-2 is the resultant call.

After the merge (transfer, in this case), events are sent as follows:

A1: Call Transferred, further-events

A2: Call Transferred, further-events

Issue 7 May 1998 3-57

Page 123
Image 123
Lucent Technologies 555-230-220 manual