ASAI and Release 6 Requirements

The maximum number of active domain-control associations per station is two for R6vs, R6si, and four for R6r.

For R6vs and R6si, the maximum number of associations that can control a station on a call is three; two domain-control associations and one call-control association. For R6r, the maximum number of associations that can control a station on a call is five; four domain-control associations and one call-control association.

Per ACD split domain:

Table B-3. ASAI Limits per ACD Split Domain

Capacity

R6vs and R6si

R6r

 

 

 

Active Notifications per Split Domain

3

6

Domain Controllers per Split Domain

1

1

 

 

 

 

 

 

The maximum number of active notifications per split domain is three for R6vs, R6si, and six for R6r.

The maximum number of domain controllers is one.

Per VDN domain:

Table B-4. ASAI Limits per VDN Domain

Capacity

R6vs and R6si

R6r

 

 

 

 

 

Active Notifications per VDN Domain

3

6

 

 

 

 

 

 

 

 

 

The maximum number of active notifications per VDN domain is three for R6vs, R6si, and six for R6r.

Per call:

Table B-5. ASAI Limits per Call

Capacity

R6vs and R6si

R6r

 

 

 

 

 

Adjunct-Control Associations per Call

1

1

 

Active Notif. Associations per Call

3

6

 

Domain Control Associations

12

24

 

 

 

 

 

 

 

 

 

The maximum number of adjunct-control associations per call is one.