Installation and Test for CallVisor ASAI

In the CDR System Parameters form, the CDR Call Splitting field must be enabled if charging number is desired in the Charging Event Report change to reflect transfers and conferences. Lastly, the CDR adjuncts must be administered, or CDR Call Splitting will not take affect and will therefore not affect the ASAI charging events.

Answering Machine Detection — System-Parameters Customer-Options Features Form

Reason Codes — System-Parameters Customer-Options and System Parameters Features Forms

Option for Switch-Classified Calls — System-Parameters Customer-Options Form

Flexible Billing — System-Parameters Customer-Options Form. In addition, the following optional system features must be activated to support the MultiQuest Flexible Billing feature:

ASAI for Release 5: ASAI not needed when have tandeming.

ISDN Primary Rate Interface (ISDN-PRI)

MultiQuest Flexible Billing: For a tandem ECS, the Flexible Billing option need not be active to tandem the NSF IEs to the next ECS. For a ECS providing VRU access without an AP, the Flexible Billing option need not be active to pass the NSF IEs to the VRU. The VRU must be equipped with a PRI interface and treated as if it were a trunk group to a tandem ECS.

Finally, the following optional system features will probably be used when Flexible Billing is active:

Automatic Call Distribution (ACD) — Required if call routing uses

ACD I

Call Vectoring — Required if inbound calls use Call Vectoring for routing

Selective Listening — System Parameters Customer-Options Form

Call Classification After Answer Supervision — System Parameters Features Form

For detailed instructions regarding the administration of the above features, see the DEFINITY Enterprise Communications Server Implementation document, 555-230-302.

CallVisor ASAI Link Testing

After the CallVisor ASAI link is administered and installed, perform the following tests as described in the DEFINITY Enterprise Communications Server Installation and Test for Single-Carrier Cabinets, 555-230-894, or DEFINITY Enterprise Communications Server Installation and Test for Multi-Carrier Cabinets, 555-230-112.

14-8Issue 7 May 1998

Page 378
Image 378
Lucent Technologies 555-230-220 manual CallVisor Asai Link Testing, Acd