ASAI Maintenance Capabilities

Suspend Alarms

This capability enables the adjunct to disable the ECS alarms on an ASAI link for maintenance functions.

NOTE:

Since unnecessary alarms can result in unnecessary maintenance expenses, it is recommended that all adjuncts request this capability during the shutdown sequence.

Information Flow

The adjunct makes the suspend alarms request for that particular link.

The ECS issues an ACK to notify the adjunct that it will not raise any alarms for that ASAI link.

Suspend Alarms Parameter

None for this capability

ACK (Positive Acknowledgement) Parameters

No parameters are contained in the acknowledgement for this capability.

Denial (NAK) Cause(s)

None for this capability

Protocol Error (NAK) Cause(s)

None for this capability

Issue 7 May 1998 11-3

Page 297
Image 297
Lucent Technologies 555-230-220 manual Suspend Alarms Parameter