4-28 Configuring Your Server

Option

Parameter

Description

Your Setting

Boot

[Disabled]

Indicates whether the boot monitoring

 

Monitoring

5 Minutes

function is enabled or disabled on booting.

 

 

10 Minutes

To use this function, install NEC ESMPRO

 

 

15 Minutes

Agent. Do not use this function if the system

 

 

20 Minutes

is booted from OS without installation of NEC

 

 

ESMPRO Agent or CD-ROM. Set this item to

 

 

25 Minutes

 

 

"Disabled" if ARCServe uses the Disaster

 

 

30 Minutes

 

 

Recovery Option.

 

 

35 Minutes

 

 

 

 

 

40 Minutes

 

 

 

45 Minutes

 

 

 

50 Minutes

 

 

 

55 Minutes

 

 

 

60 Minutes

 

 

Boot

[Retry 3 Times]

Appears when the boot monitoring feature is

 

Monitoring

Retry Service Boot

enabled. This item indicates the processing

 

Policy

Always Retest

at the occurrence of timeout during boot

 

 

 

monitoring.

 

 

 

If [Retry 3 times] is selected, the system is

 

 

 

reset after the occurrence of timeout and OS

 

 

 

boot is retried up to three times. The failure in

 

 

 

the third boot causes the boot to be tried from

 

 

 

the service partition.

 

 

 

If [Retry Service Boot] is selected, the system

 

 

 

is reset after the occurrence of timeout and

 

 

 

OS boot is retried up to three times. Then the

 

 

 

boot is tried from the service partition for

 

 

 

three times.

 

 

 

If [Always Reset] is selected, the system is

 

 

 

reset after the occurrence of timeout and OS

 

 

 

boot is retried repeatedly.

 

Thermal

Disabled

Indicates whether the temperature sensor

 

Sensor

[Enabled]

monitoring function is enabled or disabled.

 

BMC IRQ

Disabled

Indicates the IRQ of the BMC interrupt.

 

 

5

 

 

 

10

 

 

 

[11]

 

 

Post Error

Disabled

Indicates whether POST is aborted once at

 

Pause

[Enabled]

the end of POST if an error occurs during the

 

 

 

execution of POST.

 

AC-LINK

Stay Off

Indicates the AC-LINK function. Shows the

 

 

[Last State]

state of the power of the server.

 

 

Power On

 

 

 

 

[

]: Factory-set