3-20 Setting Up Your Server

„For the distance between the mount faces at the front and rear of the rack being 760 or 900 mm:

Fix the arm bracket with four screws D and four washers B at the position shown in the figure below (the figure below shows the example with the distance between the mount faces at the front and rear of the rack being 900 mm).

 

Arm bracket (900)

18.

Push the server into the rack once to check the installation position.

NOTE: Make sure that the four screw holes at the upper left and right sides on the front of the server are fit to the core nuts installed in step 2. If the four positions are not fit at all, the slide rail assembly or the core nuts may be installed incorrectly. If so, the adjacent units cannot be installed without clearance. Confirm the installation positions and make the reinstallation from the first step.

19.Pull out or push the server into the rack for several times to confirm that the slides move smoothly.

20.

Fix the server to the rack with four screws C and four washers A.

 

Screws C and Washers A