8-4 Troubleshooting

STATUS Lamp

The STATUS lamp stays lit in green when the server is in successful operation. When the STATUS lamp is unlit or lit/flashing in amber, it indicates that the server has failed.

The following table lists indications of the STATUS lamp, descriptions, and actions to take.

NOTES:

„If the server has the NEC ESMPRO or Off-line Maintenance Utility installed, you can view the error log to identify the cause of a trouble.

„To cycle power to the server, shut down the server from the OS and reboot it, if available. If the shutdown from the OS is not available, reset or execute the forced shut down or disconnect and connect the power cord to reboot the server.

STATUS lamp

STATUS lamp

Description

Action

indication

 

 

 

Lit in green

The server is in successful

None

 

operation.

 

Flashing in

The server is in operation with

Use the BIOS setup utility, SETUP, to

green

 

its memory or CPU degraded.

identify the degraded device and

 

A single-bit error occurred

replace it as soon as possible.

 

 

frequently.

 

Unlit

The server is off-powered.

Power on the server.

 

POST is in progress.

Wait for a while. The STATUS lamp will

 

 

 

light in a few seconds after POST

 

 

 

completion.

 

A CPU error occurred.

Cycle power to the server. If POST

 

A CPU thermal error was

displays an error message, take a note

 

detected. (Thermal-Trip)

on the message and contact your

 

A watchdog timer has timed out.

service representative.

 

An uncorrectable memory error

 

 

was detected.

 

 

A PCI system error occurred.

 

 

A PCI parity error occurred.

 

 

A CPU bus error occurred.

 

 

Memory dumping is requested.

Wait until memory dumping completes.