STATUS Lamp
The STATUS lamp stays lit in green when the server is in successful operation. When the STATUS lamp is unlit or lit/flashing in amber, it indicates that the server has failed.
The following table lists indications of the STATUS lamp, descriptions, and actions to take.
NOTES:
If the server has the NEC ESMPRO or
To cycle power to the server, shut down the server from the OS and reboot it, if available. If the shutdown from the OS is not available, reset or execute the forced shut down or disconnect and connect the power cord to reboot the server.
STATUS lamp
STATUS lamp | Description | Action | ||
indication | ||||
|
|
| ||
Lit in green | The server is in successful | None | ||
| operation. |
| ||
Flashing in | • | The server is in operation with | Use the BIOS setup utility, SETUP, to | |
green |
| its memory or CPU degraded. | identify the degraded device and | |
| • | A | replace it as soon as possible. | |
|
| frequently. |
| |
Unlit | The server is | Power on the server. | ||
| POST is in progress. | Wait for a while. The STATUS lamp will | ||
|
|
| light in a few seconds after POST | |
|
|
| completion. | |
| A CPU error occurred. | Cycle power to the server. If POST | ||
| A CPU thermal error was | displays an error message, take a note | ||
| detected. | on the message and contact your | ||
| A watchdog timer has timed out. | service representative. | ||
| An uncorrectable memory error |
| ||
| was detected. |
| ||
| A PCI system error occurred. |
| ||
| A PCI parity error occurred. |
| ||
| A CPU bus error occurred. |
| ||
| Memory dumping is requested. | Wait until memory dumping completes. |