Troubleshooting 8-19

 

 

 

 

 

 

 

 

 

 

Error

Error message

Recommended Action

code

 

 

 

 

8120

Unsupported DIMM detected in DIMM group

Contact your service representative to

 

#1.

replace the four DIMMs in the relevant

8121

Unsupported DIMM detected in DIMM group

group.

 

 

 

#2.

 

 

 

8122

Unsupported DIMM detected in DIMM group

 

 

 

 

#3.

 

 

 

8130

Mismatch DIMM detected in DIMM group #1.

See the labels put on the DIMMs to make

8131

Mismatch DIMM detected in DIMM group #2.

sure that the DIMMs of the same type are

8132

Mismatch DIMM detected in DIMM group #3.

installed in groups.

If DIMMs of different

types are installed in one or more groups,

 

 

 

 

contact the service representative to replace

 

 

DIMMs properly.

 

 

8140

DIMM group #1 with error is enabled.

Contact your service representative to

8141

DIMM group #2 with error is enabled.

replace the four DIMMs in the relevant

8142

DIMM group #3 with error is enabled.

group.

 

 

8150

NVRAM Cleared By Jumper.

Turn off the power.

Then recover the

8151

Password Cleared By Jumper.

jumper setting to the original setting.

8160

Mismatch Processor Speed detected on

Check the frequency of the CPU. If it is

 

Processor 1.

unknown, contact your service

8161

Mismatch Processor Speed detected on

representative.

 

 

 

Processor 2.

 

 

 

8162

Mismatch Processor Speed detected on

 

 

 

 

Processor 3.

 

 

 

8163

Mismatch Processor Speed detected on

 

 

 

 

Processor 4.

 

 

 

8170

Processor 1 not operating at intended

 

 

 

 

frequency

 

 

 

8171

Processor 2 not operating at intended

 

 

 

 

frequency

 

 

 

8172

Processor 3 not operating at intended

 

 

 

 

frequency

 

 

 

8173

Processor 4 not operating at intended

 

 

 

 

frequency

 

 

 

817F

All processors not operating at intended

 

 

 

 

frequency

 

 

 

8200

Online Spare Memory was not ready.

DIMM type mismatch is detected when the

 

 

online spare memory feature is enabled.

 

 

Contact your service representative.

8201

Mirroring Memory was not ready.

DIMM type mismatch is detected or

 

 

unnecessary installation in group #2 is

 

 

detected when the online spare memory

 

 

feature is enabled. Check the DIMM type or

 

 

installation. If the error cannot be corrected,

 

 

contact your service representative.

Page 257
Image 257
NEC 140Rc-4 manual Troubleshooting