![](/images/new-backgrounds/1172300/172300657x1.webp)
Upgrading Your Server 9-43
8.Connect the cables to the PCI board while firmly holding the PCI board with your hand.
9.Slowly close the tab to secure the PCI board. The PCI Slot Power lamp flashes once, and then goes on.
NOTES:
If the server runs on Windows 2000, the operating system automatically recognizes the additionally installed PCI board and installs the driver.
If an error occurred in the installed board or slot, the PCI Slot Fault lamp goes on (amber).
Be sure to close the tab slowly and correctly. Abruptly closing the tab may cause the system to fail to recognize the PCI board.
10.Reinstall the rear access cover and place the server into the rack.
11.Take the following steps to check if the additionally installed PCI board is recognized and operating properly:
(1)Select [Control Panel], [Administractive Tools], [Computer Management], and [Device Manager] in the order to start the Device Manager.
(2)Move the cursor to the added board.