Troubleshooting 8-23

Fail to power of the server / SLEEP switch is disabled:

Is the POWER switch or SLEEP switch enabled?

Restart the server and start the BIOS setup utility.

<Menu to check: [Security] - [Power Switch Inhibit]> Is the server running in the Secure Mode?

The POWER switch and the SLEEP switch are disabled in the Secure Mode.

(Forced shutdown is also not available.) To release the Secure Mode, enter the password specified with the BIOS setup utility.

POST fails to complete:

Is the DIMM board installed?

At least four DIMM boards are required for operation. Is the memory size large?

The memory check may take a few seconds if the memory size is large. Wait for a while.

Did you perform any keyboard or mouse operation immediately after you started the server?

If you perform any keyboard or mouse operation immediately after start-up, POST may accidentally detect a keyboard controller error and stops proceeding. In such a case, restart the server once again. Do not perform any keyboard or mouse operation until the BIOS start-up message appears when you restart the server.

Does the server have contains appropriate memory boards or PCI devices?

Operation of the server with unauthorized devices is not guaranteed.

Page 261
Image 261
NEC 140Rc-4 manual Fail to power of the server / Sleep switch is disabled, Post fails to complete