Troubleshooting 8-17

Error

Error message

Recommended Action

code

 

 

0B50

Processor #1 with error taken off line.

The CPU is degraded. Contact your

0B51

Processor #2 with error taken offline.

service representative.

0B52

Processor #3 with error taken offline.

 

0B53

Processor #4 with error taken offline.

 

0B5F

Forced to use Processor with error

Because an error is detected in every CPU,

 

 

the system is forcibly started. Contact your

 

 

service representative.

0B60

DIMM group #1 has been disabled

Contact your service representative.

0B61

DIMM group #2 has been disabled

 

0B62

DIMM group #3 has been disabled

 

0B70

The error occurred during temperature sensor

Contact your service representative.

 

reading.

 

0B71

System Temperature out of the range.

A fan failure or fan clogging may occur.

 

 

Contact your service representative to

 

 

request the maintenance.

0B74

The error occurred during voltage sensor

Contact your service representative.

 

reading.

 

0B75

System voltage out of the range.

 

0B78

The error occurred during fan sensor reading

 

0B7C

The error occurred during redundant power

Contact you service representative to

 

module confirmation

replace the power supply unit.

0B7D

The normal operation can't be guaranteed with

Contact you service representative to add an

 

use of only one PSU

additional power supply unit or replace the

 

 

existing power supply unit.

0B80

BMC Memory Test Failed.

Turn off the power once and then on again to

0B81

BMC Firmware Code Area CRC check failed.

start the server. If the error cannot be

 

 

corrected, contact your service

0B82

BMC core hardware failure.

representative.

0B83

BMC IBF or OBF check failed.

 

0B8A

BMC SEL area full.

 

0B8B

BMC progress check timeout.

 

0B8C

BMC command access failed.

 

0B8D

Could not redirect the console - BMC Busy -

 

0B8E

Could not redirect the console - BMC Error -

 

0B8F

Could not redirect the console - BMC

 

 

Parameter Error -

 

0B90

BMC Platform Information Area corrupted.

 

0B91

BMC update firmware corrupted.

 

0B92

Internal Use Area of BMC FRU corrupted.

All the commands and functions other than

 

 

the FRU command and the EMP function

 

 

can be used. This is not a fatal error. Turn

 

 

off the power once and then on again to

 

 

restart the server. If the error cannot be

 

 

corrected, contact your service

 

 

representative.

0B93

BMC SDR Repository empty.

Turn off the power once and then on again to

 

 

restart the server. If the error cannot be

 

 

corrected, contact your service

 

 

representative.

Page 255
Image 255
NEC 140Rc-4 manual Contact you service representative to add an