Upgrading Your Server 9-33
NOTES:
The insulators are installed between the PCI board slots. They are
for protecting the PCI board already been installed. Take care not to
remove or damage the insulator when installing or removing the
PCI board. If the insulator is taken off, reinstall the insulator in
place.
After installed the long board, secure it with the lock on the upper
part of the guide rail.
8. Connect the cables to the PCI board while firmly holding the PCI board with your hand. 9. Slowly close the tab to secure the PCI board. The PCI Slot Power lamp flashes once and
then, goes on.
NOTES:
If the server runs on Windows Server 2003 or Windows 2000, the
operating system automatically recognizes the additionally installed
PCI board and installs the driver.
If an error occurred in the installed board or slot, the PCI Slot Fault
lamp goes on (amber).
Be sure to close the tab slowly and correctly. Abruptly closing the
tab may cause the system to fail to recognize the PCI board.
10. Reinstall the rear access cover and place the server into the rack. 11. Take the following steps to check if the additionally installed PCI board is recognized and
operating properly:
(1) Select [Control Panel], [Administractive Tools], [Computer Management], and
[Device Manager] in the order to start the Device Manager.
(2) Move the cursor to the added board.