| High Performance Two Port 10/100 Managed Ethernet Switch with |
| Datasheet |
|
|
BITS | DESCRIPTION |
|
|
7 | Frame Too Long. When set, this bit indicates that the frame length exceeds the maximum Ethernet |
| specification of 1518 bytes. This is only a frame too long indication and will not cause the frame |
| reception to be truncated. |
|
|
6 | Collision Seen. When set, this bit indicates that the frame has seen a collision after the collision |
| window. This indicates that a late collision has occurred. |
|
|
5 | Frame Type. When set, this bit indicates that the frame is an |
| in the frame is greater than 1500). When reset, it indicates the incoming frame was an 802.3 type |
| frame. This bit is not set for Runt frames less than 14 bytes. |
|
|
4 | Receive Watchdog |
| 2048 bytes through 2560 bytes, therefore expiring the Receive Watchdog Timer. |
|
|
3 | MII Error. When set, this bit indicates that a receive error was detected during frame reception. |
|
|
2 | Dribbling Bit. When set, this bit indicates that the frame contained a |
| This error is reported only if the number of dribbling bits in the last byte is at least 3 in the 10 Mbps |
| operating mode. This bit will not be set when the collision seen bit[6] is set. If set and the CRC error |
| bit is [1] reset, then the packet is considered to be valid. |
|
|
1 | CRC Error. When set, this bit indicates that a CRC error was detected. This bit is also set when the |
| RX_ER pin is asserted during the reception of a frame even though the CRC may be correct. This bit |
| is not valid if the received frame is a Runt frame, or a late collision was detected or when the |
| Watchdog |
|
|
0 | Reserved. These bits are reserved. Reads 0 |
|
|
9.9.4Stopping and Starting the Receiver
To stop the receiver, the host must clear the RXEN bit in the Host MAC Control Register (HMAC_CR). When the receiver is halted, the RXSTOP_INT will be pulsed and reflected in the Interrupt Status Register (INT_STS). Once stopped, the host can optionally clear the RX Status and RX Data FIFOs. The host must
9.9.5Receiver Errors
If the Receiver Error (RXE) flag is asserted in the Interrupt Status Register (INT_STS) for any reason, the receiver will continue operation. RX Error (RXE) will be asserted under the following conditions:
A host underrun of RX Data FIFO
A host underrun of the RX Status FIFO
An overrun of the RX Status FIFO
It is the duty of the host to identify and resolve any error conditions.
Revision 1.4 | 136 | SMSC LAN9312 |
| DATASHEET |
|