High Performance Two Port 10/100 Managed Ethernet Switch with
Datasheet
14.5.2.5Port x MAC Receive 65 to 127 Byte Count Register (MAC_RX_65_TO_127_CNT_x)
Register #: | Port0: 0412h | Size: | 32 bits | |
| Port1: | 0812h |
|
|
| Port2: | 0C12h |
|
|
This register provides a counter of received packets between the size of 65 to 127 bytes. The counter is cleared upon being read.
BITS |
| DESCRIPTION | TYPE | DEFAULT |
|
|
|
| |
31:0 | RX 65 to 127 Bytes | RC | 00000000h | |
| Count of packets (including bad packets) that have between 65 and 127 |
|
| |
| bytes. |
|
|
|
| Note: | This counter will stop at its maximum value of FFFF_FFFFh. |
|
|
|
| Minimum rollover time at 100Mbps is approximately 487 hours. |
|
|
|
|
|
|
|
Note: A bad packet is defined as a packet that has an FCS or Symbol error. For this counter, a packet that is not an integral number of bytes is rounded down to the nearest byte.
Revision 1.4 | 326 | SMSC LAN9312 |
| DATASHEET |
|