14.2.6Switch Fabric
This section details the memory mapped System CSR’s which are related to the Switch Fabric. The flow control of all three ports of the switch fabric can be configured via the memory mapped System CSR’s MANUAL_FC_1, MANUAL_FC_2 and MANUAL_FC_MII. The MAC address used by the switch for Pause frames is configured via the SWITCH_MAC_ADDRH and SWITCH_MAC_ADDRL registers. In addition, the SWITCH_CSR_CMD, SWITCH_CSR_DATA and SWITCH_CSR_DIRECT_DATA registers serve as a memory mapped accessible interface to the full range of otherwise inaccessible switch control and status registers. A list of all the switch fabric CSRs can be seen in Table 14.12. For additional information on the switch fabric, including a full explanation on how to use the switch fabric CSR interface registers, refer to Chapter 6, "Switch Fabric," on page 55. For detailed descriptions of the Switch Fabric CSR’s that are accessible via these interface registers, refer to section Section 14.5, "Switch Fabric Control and Status Registers".
14.2.6.1Port 1 Manual Flow Control Register (MANUAL_FC_1)
Offset: | 1A0h | Size: | 32 bits |
This read/write register allows for the manual configuration of the switch Port 1 flow control. This register also provides read back of the currently enabled flow control settings, whether set manually or
Note: The flow control values in the PHY_AN_ADV_1 register (see Section 14.4.2.5, on page 293) within the PHY are not affected by the values of this register.
BITS | DESCRIPTION | TYPE | DEFAULT |
|
|
|
|
31:7 | RESERVED | RO | - |
|
|
|
|
6 | Port 1 Backpressure Enable (BP_EN_1) | R/W | |
| This bit enables/disables the generation of |
|
|
| switch Port 1. |
|
|
| 0: Disable backpressure |
|
|
| 1: Enable backpressure |
|
|
|
|
|
|
5 | Port 1 Current Duplex (CUR_DUP_1) | RO | |
| This bit indicates the actual duplex setting of switch Port 1. |
|
|
| 0: |
|
|
| 1: |
|
|
|
|
|
|
4 | Port 1 Current Receive Flow Control Enable (CUR_RX_FC_1) | RO | |
| This bit indicates the actual receive flow setting of switch Port 1. |
|
|
| 0: Flow control receive is currently disabled |
|
|
| 1: Flow control receive is currently enabled |
|
|
|
|
|
|
3 | Port 1 Current Transmit Flow Control Enable (CUR_TX_FC_1) | RO | |
| This bit indicates the actual transmit flow setting of switch Port 1. |
|
|
| 0: Flow control transmit is currently disabled |
|
|
| 1: Flow control transmit is currently enabled |
|
|
|
|
|
|
2 | Port 1 | R/W | |
| When the MANUAL_FC_1 bit is set, or |
|
|
| enables/disables the detection of |
|
|
| 0: Disable flow control receive |
|
|
| 1: Enable flow control receive |
|
|
|
|
|
|