High Performance Two Port 10/100 Managed Ethernet Switch with
Datasheet
14.5.2.8Port x MAC Receive 512 to 1023 Byte Count Register (MAC_RX_512_TO_1023_CNT_x)
Register #: | Port0: 0415h | Size: | 32 bits | |
| Port1: | 0815h |
|
|
| Port2: | 0C15h |
|
|
This register provides a counter of received packets between the size of 512 to 1023 bytes. The counter is cleared upon being read.
BITS |
| DESCRIPTION | TYPE | DEFAULT |
|
|
|
| |
31:0 | RX 512 to 1023 Bytes | RC | 00000000h | |
| Count of packets (including bad packets) that have between 512 and 1023 |
|
| |
| bytes. |
|
|
|
| Note: | This counter will stop at its maximum value of FFFF_FFFFh. |
|
|
|
| Minimum rollover time at 100Mbps is approximately 3047 hours. |
|
|
|
|
|
|
|
Note: A bad packet is defined as a packet that has an FCS or Symbol error. For this counter, a packet that is not an integral number of bytes is rounded down to the nearest byte.
SMSC LAN9312 | 329 | Revision 1.4 |
| DATASHEET |
|