High Performance Two Port 10/100 Managed Ethernet Switch with
Datasheet
Table 4.2
STRAP NAME | DESCRIPTION | PIN / DEFAULT | |
VALUE | |||
|
| ||
|
|
| |
manual_FC_strap_2 | Port 2 Manual Flow Control Enable Strap: Configures the | 0b | |
| default value of the Port 2 |
| |
| Select (MANUAL_FC_2) bit in the Port 2 Manual Flow |
| |
| Control Register (MANUAL_FC_2). When configured low, |
| |
| flow control is determined by |
| |
| and symmetric PAUSE is advertised (bit 10 of the Port x |
| |
|
| ||
| (PHY_AN_ADV_x) is set). |
| |
| When configured high, flow control is determined by the |
| |
|
| ||
|
| ||
| Enable (RX_FC_2) bits, and symmetric PAUSE is not |
| |
| advertised (bit 10 of the Port x PHY |
| |
| Advertisement Register (PHY_AN_ADV_x) is cleared). |
| |
|
|
| |
BP_EN_strap_mii | Port 0(Host MAC) Backpressure Enable Strap: | 1b | |
| Configures the default value for the Port 0 Backpressure |
| |
| Enable (BP_EN_MII) bit of the Port 0(Host MAC) Manual |
| |
|
| ||
| configured low, backpressure is disabled. When configured |
| |
| high, backpressure is enabled. |
| |
|
|
| |
FD_FC_strap_mii | Port 0(Host MAC) | 1b | |
| Strap: Configures the default of the TX_FC_MII and |
| |
| RX_FC_MII bits in the Port 0(Host MAC) Manual Flow |
| |
| Control Register (MANUAL_FC_MII) which are used when |
| |
| manual |
| |
| configured low, flow control is disabled on RX/TX. When |
| |
| configured high, flow control is enabled on RX/TX. |
| |
|
|
| |
manual_FC_strap_mii | Port 0(Host MAC) Manual Flow Control Enable Strap: | 0b | |
| Configures the default value of the MANUAL_FC_MII bit in |
| |
|
| ||
| (MANUAL_FC_MII). When configured low, flow control is |
| |
| determined by Virtual |
| |
| configured high, flow control is determined by TX_FC_MII |
| |
| and RX_FC_MII bits in the Port 0(Host MAC) Manual Flow |
| |
|
| ||
|
|
| |
SQE_test_disable_strap_mii | SQE Heartbeat Disable Strap: Configures the Signal | 0b | |
| Quality Error (Heartbeat) test function by controlling the |
| |
| default value of the SQEOFF (bit 0) of the Virtual PHY |
| |
|
| ||
| (VPHY_SPECIAL_CONTROL_STATUS). When configured |
| |
| low, SQEOFF defaults to 0 and SQE test is enabled. When |
| |
| configured high, SQEOFF defaults to 1 and SQE test is |
| |
| disabled. |
| |
|
|
|
SMSC LAN9312 | 45 | Revision 1.4 |
| DATASHEET |
|