For details, see
Enabling DME wipe operations for sub
By factory default, DME wipe operations are inhibited for sub background. To enable them, in the Engineering Setup >Switcher >Config menu, set [DME Wipe Sub Enable] to On.
This enables DME wipe operations for sub background.
This setting applies to the whole control panel (all M/E banks and PGM/PST bank).
Note
If a DME wipe for sub is recalled in a snapshot or keyframe, the image will not be handled correctly.
Inhibiting utility 2 bus signal selection
In Multi Program 2 mode, you can inhibit other uses of the utility 2 bus signal in order to use the signal as the background for sub.
This setting applies to the whole control panel (all M/E banks and PGM/PST bank).
In the Engineering Setup >Panel >Config >MP2 Main/Sub Assign menu, set [Util2 Inhibit] to On.
This inhibits operations of selecting from the background B row while holding down the [UTIL] button in the
Including Multi Program 2 data in recall operations of keyframes and snapshots
In the Engineering Setup >Switcher >Config menu, set [Recall M/E Config] to On.
When a keyframe or snapshot is stored or recalled, the following data is included.
M/E Config, PGM Config, M/E Output Assign, and Key PVW Config
For details of the above data, see “Setting the operating mode for each switcher bank” (page 233) and “Assigning output signals for Multi Program 2 mode” (page 233).
This setting applies to the whole control panel (all M/E banks and PGM/PST bank).
Note
M/E Config data is saved, even when this setting is Off.
238 Multi Program 2