This confirms the entry, and the selected region name and the set transition rate appear in the numeric keypad control block display.
The transition control block display of the same bank (M/E or PGM/PST) also shows the setting.
To enter a difference from the current value
After pressing the
To change the sign (+ or
Setting the transition rate by a menu operation
1 In the M/E or PGM/PST menu, select first VF7 ‘Misc,’ then HF1 ‘Transition.’
The Transition menu appears.
2 Select any transition type in the <Transition Type> group.
3 Turn the knob to set the transition rate.
Knob | Parameter | Adjustment | Setting values |
|
|
|
|
1 | Transition Rate | Transition Rate | 0 to 999 (frame count) |
|
|
|
|
Displaying the transition rates in a menu and changing the settings
For each of the M/E and PGM/PST banks, you can display the transition rate, independent key transition rate and
For more details, see “Displaying a List of Transition Rates and Changing the Settings” (page 553).
Pattern Limit
There are two ways of setting a pattern limit: either by operating the fader lever to save the fader position, or by using the Wipe menu or DME Wipe menu to access the Edge/Direction menu for the M/E or PGM/PST bank.
For an overview of the pattern limits, see page 46.
Executing a Transition 355