the
In the case of a wipe pattern selected for a mask, the modifier [Edge] and [Direction] settings are not available.
Utility 1 Bus: signal selected on the utility 1 bus
When you selected [Utility 1 Bus], hold down the [UTIL] button in the
Note
To enable the [UTIL] button, its operation mode must be set to [Hold] beforehand. (See “Operation Settings (Operation Menu)” in Chapter 16 (Volume 2).)
4 Set the mask source parameters.
• When wipe is selected
Knob | Parameter | Adjustment | Setting values |
|
|
|
|
1 | Size | Pattern size | 0.00 to 100.00 |
|
|
|
|
2 | Soft | Edge softness | 0.00 to 100.00 |
|
|
|
|
• When utility 1 bus is selected
Knob | Parameter | Adjustment | Setting values |
|
|
|
|
1 | Clip | Reference level for creating mask | +109.59 to |
|
| signal |
|
|
|
|
|
2 | Gain | Gain | |
|
|
|
|
5 To invert the black and white sense of the mask source, press the [Mask Invert] button, turning it on.
Applying a DME Effect to a Key
Note
For one M/E bank, DME effects (including DME wipes) can be used in up to two places on the dedicated interface and in only one place on the SDI interface simultaneously.
When combining the SDI interface with the dedicated interface, you can apply DME effects to a maximum of three keys. (Requires a setting in setup.)
400 Key Setting Operations Using Menus