Keys 4 Chapter

the M/E-1 >Wipe menu (see page 438), then return to this M/E-1 >Key1 menu.

In the case of a wipe pattern selected for a mask, the modifier [Edge] and [Direction] settings are not available.

Utility 1 Bus: signal selected on the utility 1 bus

When you selected [Utility 1 Bus], hold down the [UTIL] button in the M/E-1 bank cross-point control block, and select the signal with the background A bus buttons. While the [UTIL] button is pressed, the background A bus switches to the utility 1 bus.

Note

To enable the [UTIL] button, its operation mode must be set to [Hold] beforehand. (See “Operation Settings (Operation Menu)” in Chapter 16 (Volume 2).)

4 Set the mask source parameters.

• When wipe is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Size

Pattern size

0.00 to 100.00

 

 

 

 

2

Soft

Edge softness

0.00 to 100.00

 

 

 

 

• When utility 1 bus is selected

Knob

Parameter

Adjustment

Setting values

 

 

 

 

1

Clip

Reference level for creating mask

+109.59 to –7.31

 

 

signal

 

 

 

 

 

2

Gain

Gain

–100.00 to +100.00

 

 

 

 

5 To invert the black and white sense of the mask source, press the [Mask Invert] button, turning it on.

Applying a DME Effect to a Key

Note

For one M/E bank, DME effects (including DME wipes) can be used in up to two places on the dedicated interface and in only one place on the SDI interface simultaneously.

When combining the SDI interface with the dedicated interface, you can apply DME effects to a maximum of three keys. (Requires a setting in setup.)

400 Key Setting Operations Using Menus